提高变电站监控信息规范率

来源:电工电气发布时间:2017-02-18 08:18 浏览次数:8
提高变电站监控信息规范率
 
曹娜,房艺丹,徐志静
(国网吴忠供电公司,宁夏 吴忠 751100)
 
    摘 要:提高变电站监控信息规范率,可有效提升监控效率。选取17 座变电站进行统计分析,发现造成变电站监控信息规范率低的主要原因是监控信息点表标准不统一。依据《变电站监控系统信息采集规范》和《变电站典型信息表》,结合地区电网情况,编制各电压等级的变电站典型信息点表,并根据典型信息点表优化各站监控信息。经实际验证,有效提升了变电站监控信息的规范率。
    关键词:变电站;监控信息;规范率;典型信息点表
    中图分类号:TM63       文献标识码:A       文章编号:1007-3175(2017)02-0063-04
 
Improved Standard Rate of Substation Monitoring Information
 
CAO Na, FANG Yi-dan, XU Zhi-jing
(State Grid Wuzhong Power Supply Company, Wuzhong 7511 00, China)
 
    Abstract: The improved standard rate of substation monitoring information could raise the monitoring efficiency. The seventeen substations were carried out statistical analysis. The main reason causing the low substation monitoring information standard rate was disunity monitoring information point table standard. According to substation monitoring information collection standard and substation typical information table, combined with the regional power grid situation, substation typical information point tables of every voltage classes were established, and each substation monitoring information was optimized according to the information point tables. The practical verification improves the standard rate of substation monitoring information effectively.
    Key words: substation; monitoring information; standard rate; typical information point table
 
参考文献
[1] 王慧娟,陈冬雪,秦志沁. 无人值班变电站集控中心监控信息标准化设计[J]. 山西电力,2013(5):50-53.
[2] 徐鹤勇,张星,刘一峰. 宁夏330 kV主网监控信息优化方法[J]. 宁夏电力,2014(6):57-60.
[3] 杨劲松,杜长军. 浅谈变电站监控信息优化整合[J]. 科技创新与应用,2013(36):129.